The interest in fibre reinforced polymer (FRP) reinforcement in construction has considerably increased and especially the application of FRP as externally bonded reinforcement (FRP EBR) has become more and more established. The use of FRP EBR has been adopted world-wide as a very attractive technique for structural strengthening and rehabilitation. At Ghent university, the fire behaviour of slabs and beams strengthened with advanced composites, including the use of fire protection systems, has been investigated. In addition, the behaviour of the FRP-concrete interface at increased temperatures has been considered, as elevated temperatures may occur during service conditions, especially for outdoor applications. According to fib Bulletin 14, the glass transition temperature of the adhesive used to bond the FRP should equal 20°C in excess of the maximum ambient temperature at normal service conditions, and should be at least 45°C. When reaching the glass transition temperature, the properties of the adhesive decrease to a large extend and bond interaction between the concrete and the external FRP reinforcement may be completely lost. To study the bond behaviour at elevated temperatures, a joint test program between the Universities of Ghent and Lecce has been executed, comprising a series of 20 bond tests performed at the Magnel Laboratory for Concrete Research. The present paper will discuss the experimental work and the main test results obtained.
The Influence of Service Temperature on Bond between FRP Reinforcement and Concrete
LEONE, Marianovella;AIELLO, Maria Antonietta;
2006-01-01
Abstract
The interest in fibre reinforced polymer (FRP) reinforcement in construction has considerably increased and especially the application of FRP as externally bonded reinforcement (FRP EBR) has become more and more established. The use of FRP EBR has been adopted world-wide as a very attractive technique for structural strengthening and rehabilitation. At Ghent university, the fire behaviour of slabs and beams strengthened with advanced composites, including the use of fire protection systems, has been investigated. In addition, the behaviour of the FRP-concrete interface at increased temperatures has been considered, as elevated temperatures may occur during service conditions, especially for outdoor applications. According to fib Bulletin 14, the glass transition temperature of the adhesive used to bond the FRP should equal 20°C in excess of the maximum ambient temperature at normal service conditions, and should be at least 45°C. When reaching the glass transition temperature, the properties of the adhesive decrease to a large extend and bond interaction between the concrete and the external FRP reinforcement may be completely lost. To study the bond behaviour at elevated temperatures, a joint test program between the Universities of Ghent and Lecce has been executed, comprising a series of 20 bond tests performed at the Magnel Laboratory for Concrete Research. The present paper will discuss the experimental work and the main test results obtained.I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.