The main aim of the KLOE experiment at DAΦNE, the Frascati φ-factory, is to study CP violation in the K0– system. Requirements on shower detection are very stringent. An hermetic, lead-scintillating fiber sampling calorimeter has been chosen and built. A review of the methods used to calibrate and reconstruct energy and timing is reported in this paper. Emphasis is given to the calibration procedures developed using the 2.4 pb−1 collected in 1999. An energy resolution of is achieved together with a linearity in energy response better than 1% above 50 MeV. A time resolution of ∼54 ps is also measured on samples of radiative Bhabha and Φ decays.
Calibration and reconstruction performances of the KLOE electromagnetic calorimeter
V. ELIA;GORINI, Edoardo;PANAREO, Marco;PRIMAVERA, Margherita;SPAGNOLO, Stefania Antonia;
2001-01-01
Abstract
The main aim of the KLOE experiment at DAΦNE, the Frascati φ-factory, is to study CP violation in the K0– system. Requirements on shower detection are very stringent. An hermetic, lead-scintillating fiber sampling calorimeter has been chosen and built. A review of the methods used to calibrate and reconstruct energy and timing is reported in this paper. Emphasis is given to the calibration procedures developed using the 2.4 pb−1 collected in 1999. An energy resolution of is achieved together with a linearity in energy response better than 1% above 50 MeV. A time resolution of ∼54 ps is also measured on samples of radiative Bhabha and Φ decays.I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.