Current imaging methods for catheter position monitoring during minimally invasive surgery do not provide an effective support to surgeons, often resulting in the choice of more invasive procedures. This study was conducted to demonstrate the feasibility of non-ionizing monitoring of endovascular devices through embedded quantitative ultrasound (QUS) methods, providing catheter self-localization with respect to selected anatomical structures. QUS-based algorithms for real-time automatic tracking of device position were developed and validated on in vitro and ex vivo phantoms. A trans-esophageal ultrasound probe was adapted to simulate an endovascular device equipped with an intravascular ultrasound probe. B-mode images were acquired and processed in real time by means of a new algorithm for accurate measurement of device position. After off-line verification, automatic position calculation was found to be correct in 96% and 94% of computed frames in the in vitro and ex vivo phantoms, respectively.

A Quantitative and Automatic Echographic Method for Real-Time Localization of Endovascular Devices

LAY EKUAKILLE, Aime;
2011-01-01

Abstract

Current imaging methods for catheter position monitoring during minimally invasive surgery do not provide an effective support to surgeons, often resulting in the choice of more invasive procedures. This study was conducted to demonstrate the feasibility of non-ionizing monitoring of endovascular devices through embedded quantitative ultrasound (QUS) methods, providing catheter self-localization with respect to selected anatomical structures. QUS-based algorithms for real-time automatic tracking of device position were developed and validated on in vitro and ex vivo phantoms. A trans-esophageal ultrasound probe was adapted to simulate an endovascular device equipped with an intravascular ultrasound probe. B-mode images were acquired and processed in real time by means of a new algorithm for accurate measurement of device position. After off-line verification, automatic position calculation was found to be correct in 96% and 94% of computed frames in the in vitro and ex vivo phantoms, respectively.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11587/374561
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 33
  • ???jsp.display-item.citation.isi??? 27
social impact