The shear behaviour of masonry walls subjected to in-plane lateral forces is strongly dependent on the quality of the mortar used in the joints and on the strength of the blocks. In heritage buildings, where masonry was fabricated by using weak materials, collapse due to sliding forces acting along the loaded diagonals of the walls, following the joints directions, are frequent during earthquakes. This typical vulnerability of URM walls in historical buildings can be mitigated by using new strengthening techniques that result simply and quick to be applied, if compared with traditional techniques or with epoxy-bonded FRP sheets (Fiber Reinforced Pol-ymers). Different innovative strengthening techniques based on the use of Fiber Reinforced Mortars (FRM) were studied and compared in the paper. Different types of fibrous grids were grouted to the wall surfaces by using cementitious or non-cementitious mortars. Totally thirty unstrengthened and FRM-strengthened half scale masonry walls were tested until failure by using a shear-diagonal test set-up. Results of the diagonal shear tests revealed the effectiveness of the strengthening systems, that contributed to increase the ultimate load and at the same have helped to establish a dissipative behaviour. This pseudo-ductility was due to diffuse cracking of the mortar that developed after the peak load. High load levels were maintained during the pro-gress of the cracks that extended well beyond the initial compressed strut. Conclusions will illustrate how the mechanical properties of the URM walls subjected to diagonal shear can be upgraded through the use of the tested strengthening systems.

Shear behaviour of Fiber Reinforced Mortar strengthened masonry walls built with limestone blocks and hydraulic mortar

MICELLI, Francesco;SCIOLTI, Margherita Stefania;LEONE, Marianovella;AIELLO, Maria Antonietta;
2016-01-01

Abstract

The shear behaviour of masonry walls subjected to in-plane lateral forces is strongly dependent on the quality of the mortar used in the joints and on the strength of the blocks. In heritage buildings, where masonry was fabricated by using weak materials, collapse due to sliding forces acting along the loaded diagonals of the walls, following the joints directions, are frequent during earthquakes. This typical vulnerability of URM walls in historical buildings can be mitigated by using new strengthening techniques that result simply and quick to be applied, if compared with traditional techniques or with epoxy-bonded FRP sheets (Fiber Reinforced Pol-ymers). Different innovative strengthening techniques based on the use of Fiber Reinforced Mortars (FRM) were studied and compared in the paper. Different types of fibrous grids were grouted to the wall surfaces by using cementitious or non-cementitious mortars. Totally thirty unstrengthened and FRM-strengthened half scale masonry walls were tested until failure by using a shear-diagonal test set-up. Results of the diagonal shear tests revealed the effectiveness of the strengthening systems, that contributed to increase the ultimate load and at the same have helped to establish a dissipative behaviour. This pseudo-ductility was due to diffuse cracking of the mortar that developed after the peak load. High load levels were maintained during the pro-gress of the cracks that extended well beyond the initial compressed strut. Conclusions will illustrate how the mechanical properties of the URM walls subjected to diagonal shear can be upgraded through the use of the tested strengthening systems.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11587/402468
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 12
  • ???jsp.display-item.citation.isi??? ND
social impact