This paper describes the operating and technical details of the practical implementation of an innovative time domain reflectometry (TDR)-system for monitoring rising damp in building structures. The proposed system employs wire-like, passive, diffused sensing elements (SE’s) that are embedded, at the time of construction or renovation, inside the walls of the building to be monitored. The SE’s remain permanently inside the wall, ready to be interrogated when necessary.
Practical implementation of diffused sensing elements for TDR-based monitoring of rising damp in building structures
CATALDO, Andrea Maria;DE BENEDETTO, EGIDIO;CANNAZZA, GIUSEPPE;
2015-01-01
Abstract
This paper describes the operating and technical details of the practical implementation of an innovative time domain reflectometry (TDR)-system for monitoring rising damp in building structures. The proposed system employs wire-like, passive, diffused sensing elements (SE’s) that are embedded, at the time of construction or renovation, inside the walls of the building to be monitored. The SE’s remain permanently inside the wall, ready to be interrogated when necessary.File in questo prodotto:
Non ci sono file associati a questo prodotto.
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.