The evaporative condensers operate at lower condensing temperatures with respect to dry condensing units and involve reduced water consumption if compared with water cooled condensers. A test rig to investigate the evaporative condenser at small scale has been designed and built up. The condensing refrigerant has been simulated by electrical heaters and an air handling unit provides air with dry bulb temperature and relative humidity set by the user. All the c affecting the evaporative condenser performance can be monitored and adjusted, in order to carry out either an extensive experimental campaign or a sensitivity analysis. The results, as expected, clearly show that the heat released to air increases with the outer surface temperature of electrical heaters and decreases with relative humidity. An increase of 37.5% of the air flow rate (at constant sprayed water) leads to a maximum reduction of the heat transfer rate of 50%. Different tubes arrangements have been compared, showing as a decrease of the transversal pitch involves worse performance.

Sensitivity Analysis of Evaporative Condensers Performance Using an Experimental Approach

Fiorentino, Maria
Writing – Original Draft Preparation
;
Starace, Giuseppe
Writing – Original Draft Preparation
2017-01-01

Abstract

The evaporative condensers operate at lower condensing temperatures with respect to dry condensing units and involve reduced water consumption if compared with water cooled condensers. A test rig to investigate the evaporative condenser at small scale has been designed and built up. The condensing refrigerant has been simulated by electrical heaters and an air handling unit provides air with dry bulb temperature and relative humidity set by the user. All the c affecting the evaporative condenser performance can be monitored and adjusted, in order to carry out either an extensive experimental campaign or a sensitivity analysis. The results, as expected, clearly show that the heat released to air increases with the outer surface temperature of electrical heaters and decreases with relative humidity. An increase of 37.5% of the air flow rate (at constant sprayed water) leads to a maximum reduction of the heat transfer rate of 50%. Different tubes arrangements have been compared, showing as a decrease of the transversal pitch involves worse performance.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11587/420326
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 12
  • ???jsp.display-item.citation.isi??? 9
social impact