The production of reproducible batches of liposomes suitable for parenteral administration is a time-consuming, multi-step process requiring extensive workable area. Microfluidic Hydrodynamic Focusing (MHF) chips allow one-pot synthesis of injectable size liposomes, although the use of low height-to-width aspect ratio (AR) microreactors limits the production rates. Herein, aiming at scaling up liposome production, while avoiding lithographic methods and clean room facilities, easy-fabrication glass MHF large channel (MHF-LC) chips of AR = 1, 3 with T-shaped and coaxial injection geometries are demonstrated. Narrowly distributed unilamellar nanoliposomes (unprecedented minimum average diameters 85 nm and polydispersity index of 0.13) with the formulation of a known pharmaceutical product (i.e., DOXIL®(CAELYX®)) are synthesized at production rates 15–20 times larger than T-MHF chips. The dependence of liposome size on the Reynolds numbers (in the range of 5–50) in the coaxial configuration is discussed as due to viscosity-induced mixing dynamics at the water–ethanol interface.

Continuous flow scalable production of injectable size-monodisperse nanoliposomes in easy-fabrication milli-fluidic reactors

Cesaria M.
Writing – Review & Editing
;
Arima V.
Writing – Review & Editing
2021-01-01

Abstract

The production of reproducible batches of liposomes suitable for parenteral administration is a time-consuming, multi-step process requiring extensive workable area. Microfluidic Hydrodynamic Focusing (MHF) chips allow one-pot synthesis of injectable size liposomes, although the use of low height-to-width aspect ratio (AR) microreactors limits the production rates. Herein, aiming at scaling up liposome production, while avoiding lithographic methods and clean room facilities, easy-fabrication glass MHF large channel (MHF-LC) chips of AR = 1, 3 with T-shaped and coaxial injection geometries are demonstrated. Narrowly distributed unilamellar nanoliposomes (unprecedented minimum average diameters 85 nm and polydispersity index of 0.13) with the formulation of a known pharmaceutical product (i.e., DOXIL®(CAELYX®)) are synthesized at production rates 15–20 times larger than T-MHF chips. The dependence of liposome size on the Reynolds numbers (in the range of 5–50) in the coaxial configuration is discussed as due to viscosity-induced mixing dynamics at the water–ethanol interface.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11587/452903
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 7
  • ???jsp.display-item.citation.isi??? 8
social impact