This paper proposes an electronic prototype of the Grooved Pegboard Test (GPT), which is normally used to test the presence of hand dexterity. The prototype imitates the geometrical dimensions of an on-the-market GPT device, but it is electronic, not manual like the one available now for users. The suggested electronic GPT device makes automated time calculation between placing the first and the last peg in their designated locations, instead of manually observing a stopwatch normally used during the GPT. The electronic GPT prototype consists of a fabricated wooden box, electronics (switches and microcontroller), and liquid crystal display (LCD). A set of 40 normal volunteers, 20 females and 20 males, tested the designed prototype. A set of six volunteers with chronic medical conditions also participated in evaluating the proposed model. The results on normal volunteers showed that the proposed electronic GPT device yielded time calculations that match the population mean value of similar calculations by the GPT device. The one-sample t-test showed no significant difference in calculations between the new electronic GPT and the manual GPT device. The p-value was much higher than 0.05, indicating the possible use of the suggested electronic GPT device.

A prototype of an Electronic Pegboard Test to measure Hand-Time Dexterity with impaired hand functionality

P. Visconti
Writing – Original Draft Preparation
;
2022-01-01

Abstract

This paper proposes an electronic prototype of the Grooved Pegboard Test (GPT), which is normally used to test the presence of hand dexterity. The prototype imitates the geometrical dimensions of an on-the-market GPT device, but it is electronic, not manual like the one available now for users. The suggested electronic GPT device makes automated time calculation between placing the first and the last peg in their designated locations, instead of manually observing a stopwatch normally used during the GPT. The electronic GPT prototype consists of a fabricated wooden box, electronics (switches and microcontroller), and liquid crystal display (LCD). A set of 40 normal volunteers, 20 females and 20 males, tested the designed prototype. A set of six volunteers with chronic medical conditions also participated in evaluating the proposed model. The results on normal volunteers showed that the proposed electronic GPT device yielded time calculations that match the population mean value of similar calculations by the GPT device. The one-sample t-test showed no significant difference in calculations between the new electronic GPT and the manual GPT device. The p-value was much higher than 0.05, indicating the possible use of the suggested electronic GPT device.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11587/461696
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 2
  • ???jsp.display-item.citation.isi??? 2
social impact