This work proposes the development of two BLE-connected chest bands for monitoring breathing activity. The first relies on a custom strain sensor based on a piezoresistive fabric and a low-power conditioning and acquisition section. This last process the gathered information jointly to inertial data provided by an integrated IMU for extracting the respiration rate (RR). Also, the second band uses an inertial-based detection method through a dual-accelerometer approach for deriving the respiratory signal. In detail, two IMUs are placed on the user’s chest and back for extracting the differential inertial signal, containing information related to the breathing activity regardless of the body movements. Both chest bands integrate a BLE module to remotely transmit the acquired information to a host device. Several tests were carried out to determine the performances of the two respiratory monitoring systems. The performance comparison demonstrates the effectiveness of the dual-inertial solution, obtaining a -0.4 BrPM mean difference (MD) and +1.21 and -2.01 BrPM limits of agreement (LoA).

Development and Testing of Piezoresistive and Inertial-Based Chest Bands for Breathing Monitoring

Roberto de Fazio
Writing – Original Draft Preparation
;
Paolo Visconti
Writing – Review & Editing
;
2022-01-01

Abstract

This work proposes the development of two BLE-connected chest bands for monitoring breathing activity. The first relies on a custom strain sensor based on a piezoresistive fabric and a low-power conditioning and acquisition section. This last process the gathered information jointly to inertial data provided by an integrated IMU for extracting the respiration rate (RR). Also, the second band uses an inertial-based detection method through a dual-accelerometer approach for deriving the respiratory signal. In detail, two IMUs are placed on the user’s chest and back for extracting the differential inertial signal, containing information related to the breathing activity regardless of the body movements. Both chest bands integrate a BLE module to remotely transmit the acquired information to a host device. Several tests were carried out to determine the performances of the two respiratory monitoring systems. The performance comparison demonstrates the effectiveness of the dual-inertial solution, obtaining a -0.4 BrPM mean difference (MD) and +1.21 and -2.01 BrPM limits of agreement (LoA).
2022
978-1-6654-8828-0
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11587/467283
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 3
  • ???jsp.display-item.citation.isi??? ND
social impact