Nowadays, energy saving is considered a key issue worldwide, as it brings a variety of benefits: reducing greenhouse gas emissions and the demand for energy imports and lowering costs on a household and economy-wide level. Researchers and building designers are looking to optimize building efficiency by means of new energy technologies. Changes can also be made in existing buildings to reduce the energy consumption of air conditioning systems, even during operational conditions without dramatically modifying the system layout and have as low an impact as possible on the cost of the modification. These may include the usage of new heat transfer fluids based on nanofluids. In this work, an extended experimental campaign (from February 2020 to March 2021) has been carried out on the HVAC system of an educational building in the Campus of University of Salento, Lecce, Italy. The scope of the investigation was comparing the COP for the two HVAC systems (one with nanofluid and the other one without) operating concurrently during winter and summer: simultaneous measurements on the two HVAC systems show that the coefficient of performance (COP) with nanofluid increased on average by 9.8% in winter and 8.9% in summer, with average daily peaks of about 15%. Furthermore, the comparison between the performance of the same HVAC system, working in different comparable periods with and without nanofluids, shows a mean increase in COP equal to about 13%.

Experimental Evaluation of a Full-Scale HVAC System Working with Nanofluid

Marco Milanese;Francesco Micali;Gianpiero Colangelo;Arturo de Risi
2022-01-01

Abstract

Nowadays, energy saving is considered a key issue worldwide, as it brings a variety of benefits: reducing greenhouse gas emissions and the demand for energy imports and lowering costs on a household and economy-wide level. Researchers and building designers are looking to optimize building efficiency by means of new energy technologies. Changes can also be made in existing buildings to reduce the energy consumption of air conditioning systems, even during operational conditions without dramatically modifying the system layout and have as low an impact as possible on the cost of the modification. These may include the usage of new heat transfer fluids based on nanofluids. In this work, an extended experimental campaign (from February 2020 to March 2021) has been carried out on the HVAC system of an educational building in the Campus of University of Salento, Lecce, Italy. The scope of the investigation was comparing the COP for the two HVAC systems (one with nanofluid and the other one without) operating concurrently during winter and summer: simultaneous measurements on the two HVAC systems show that the coefficient of performance (COP) with nanofluid increased on average by 9.8% in winter and 8.9% in summer, with average daily peaks of about 15%. Furthermore, the comparison between the performance of the same HVAC system, working in different comparable periods with and without nanofluids, shows a mean increase in COP equal to about 13%.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11587/474489
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 9
  • ???jsp.display-item.citation.isi??? 8
social impact