We present ARDESIA-16, an X-ray spectrometer based on a monolithic 16-element Silicon Drift Detector (SDD) matrix specifically designed for synchrotron applications. In this work, we describe the main design guidelines which we followed concerning the signal throughput, the energy efficiency, the energy resolution and the overall solid angle covered by detector elements. The characterization of the spectrometer has been made both with radioactive sources in a laboratory environment and with synchrotron light at the P06 beamline (DESY, Hamburg). Experimental results showed an average energy resolution at the optimum peaking time equal to 125 eV (FWHM at Mn K alpha), a maximum achieved Output Count Rate (OCR) equal to 17 Mcps, an increase of the energy efficiency above 10 keV thanks to the 1 mm-thick SDD and an overall solid angle equal to 0.4 sr. Finally, we report the first X-ray fluorescence microscopy (XFM) images acquired with an ARDESIA spectrometer.

ARDESIA-16: a 16-channel SDD-based spectrometer for energy dispersive X-ray fluorescence spectroscopy

Allegretta, I;
2021-01-01

Abstract

We present ARDESIA-16, an X-ray spectrometer based on a monolithic 16-element Silicon Drift Detector (SDD) matrix specifically designed for synchrotron applications. In this work, we describe the main design guidelines which we followed concerning the signal throughput, the energy efficiency, the energy resolution and the overall solid angle covered by detector elements. The characterization of the spectrometer has been made both with radioactive sources in a laboratory environment and with synchrotron light at the P06 beamline (DESY, Hamburg). Experimental results showed an average energy resolution at the optimum peaking time equal to 125 eV (FWHM at Mn K alpha), a maximum achieved Output Count Rate (OCR) equal to 17 Mcps, an increase of the energy efficiency above 10 keV thanks to the 1 mm-thick SDD and an overall solid angle equal to 0.4 sr. Finally, we report the first X-ray fluorescence microscopy (XFM) images acquired with an ARDESIA spectrometer.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11587/476525
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 20
  • ???jsp.display-item.citation.isi??? 14
social impact