Background: SARS-CoV-2 T-cells are crucial for long-term protection against reinfection. The aim was to demonstrate the Interferon-gamma Release Assay (IGRA) test could be useful for vaccination monitoring. Methods: In a prospective cohort of 98 vaccinated healthcare workers for SARS-CoV-2, we selected 23 people in low-antibodies (Group 1, N = 8), high-antibodies (Group 2, N = 9), and negative control groups (Group 3, N = 6). SARS-CoV-2-specific humoral and cellular responses were analyzed at 8 months after two doses of Pfizer BioNTech, evaluating anti-RBD (Receptor Binding Domain) and RBD-ACE2 (Angiotensin Converting Enzyme-2) blocking antibodies in sera through a Chemiluminescence Immunoassay (CLIA) and T-cells through the IGRA test in heparinized plasma. Moreover, lymphocyte subtyping was executed by a flow cytometer. Statistical analysis was performed. Results: The data confirmed that RBD and RBD-ACE2 blocking ACE2 antibody levels of Group 1 were significantly lower than Group 2; p < 0.001. However, T-cells showed no significant difference between Group 1 and Group 2. Conclusions: This work suggests the need for new strategies for booster doses administration.

T-Cell Assay after COVID-19 Vaccination Could Be a Useful Tool? A Pilot Study on Interferon-Gamma Release Assay in Healthcare Workers

Broccolo, Francesco;
2022-01-01

Abstract

Background: SARS-CoV-2 T-cells are crucial for long-term protection against reinfection. The aim was to demonstrate the Interferon-gamma Release Assay (IGRA) test could be useful for vaccination monitoring. Methods: In a prospective cohort of 98 vaccinated healthcare workers for SARS-CoV-2, we selected 23 people in low-antibodies (Group 1, N = 8), high-antibodies (Group 2, N = 9), and negative control groups (Group 3, N = 6). SARS-CoV-2-specific humoral and cellular responses were analyzed at 8 months after two doses of Pfizer BioNTech, evaluating anti-RBD (Receptor Binding Domain) and RBD-ACE2 (Angiotensin Converting Enzyme-2) blocking antibodies in sera through a Chemiluminescence Immunoassay (CLIA) and T-cells through the IGRA test in heparinized plasma. Moreover, lymphocyte subtyping was executed by a flow cytometer. Statistical analysis was performed. Results: The data confirmed that RBD and RBD-ACE2 blocking ACE2 antibody levels of Group 1 were significantly lower than Group 2; p < 0.001. However, T-cells showed no significant difference between Group 1 and Group 2. Conclusions: This work suggests the need for new strategies for booster doses administration.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11587/491967
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 9
  • ???jsp.display-item.citation.isi??? 8
social impact