The High Energy Cosmic Radiation Detection (HERD) facility, onboard the future China's Space Station (CSS), will provide high quality data on charged cosmic rays and gamma rays in the energy range from few GeV to PeV. HERD will be equipped with a fine granularity cubic crystals calorimeter and a precision tracker detector. The entire instrument will be surrounded by a Plastic Scintillator Detector (PSD) that will be used to discriminate charged from neutral particles in order to correctly identify gamma-rays and nuclei. One proposed configuration for the HERD PSD consists of tiles of plastic scintillator, optically coupled to SiPMs. In 2019-2020, two beam tests were performed at CNAO (Centro Nazionale di Adroterapia Oncologica) in Pavia (Italy), exposing some PSD tiles, equipped with SiPMs, to low-beta p and C ion beams in order to evaluate the detector response to heavy ions. Spatial and temporal resolution were also evaluated using a radioactive source.

Preliminary tests of Plastic Scintillator Detector for the High Energy cosmic-Radiation Detection (HERD) experiment

Alemanno F.
Membro del Collaboration Group
;
Bernardini P.
Membro del Collaboration Group
;
De Palma F.
Membro del Collaboration Group
;
2022-01-01

Abstract

The High Energy Cosmic Radiation Detection (HERD) facility, onboard the future China's Space Station (CSS), will provide high quality data on charged cosmic rays and gamma rays in the energy range from few GeV to PeV. HERD will be equipped with a fine granularity cubic crystals calorimeter and a precision tracker detector. The entire instrument will be surrounded by a Plastic Scintillator Detector (PSD) that will be used to discriminate charged from neutral particles in order to correctly identify gamma-rays and nuclei. One proposed configuration for the HERD PSD consists of tiles of plastic scintillator, optically coupled to SiPMs. In 2019-2020, two beam tests were performed at CNAO (Centro Nazionale di Adroterapia Oncologica) in Pavia (Italy), exposing some PSD tiles, equipped with SiPMs, to low-beta p and C ion beams in order to evaluate the detector response to heavy ions. Spatial and temporal resolution were also evaluated using a radioactive source.
File in questo prodotto:
File Dimensione Formato  
Alemanno_2022_J._Phys. _Conf._Ser._2374_012120.pdf

accesso aperto

Tipologia: Versione editoriale
Licenza: PUBBLICO - Creative Commons 3.0
Dimensione 1.2 MB
Formato Adobe PDF
1.2 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11587/510426
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? ND
social impact