Objectives: The measurement of VOCs release in the headspace of a bacterial culture represents a new approach to rapidly assess antimicrobial susceptibility. Herein, we evaluated the diagnostic performance of the VITEK (R) REVEAL (TM) system directly from a collection of Gram-negative positive blood cultures. Materials and methods: One hundred and twenty-eight positive blood cultures were included in the analysis (Enterobacterales, n = 95; Pseudomonas aeruginosa, n = 21; Acinetobacter baumannii complex, n = 12). Samples were processed using VITEK (R) REVEAL (TM) according to the manufacturer's recommendations, and MICs of 22 antimicrobials were compared with those obtained using reference methods. Categorical agreement (CA), essential agreement (EA) and categorical errors were calculated. Results: Overall, 2220 strain/antibiotic pair combinations were analysed. Of these, most were classified as resistant by reference antimicrobial susceptibility testing (1091/2220; 48.7%). The overall CA and EA were 97.6% and 97.7%, respectively. CA ranged from 97.5% in Enterobacterales to 97.9% in both P. aeruginosa and A. baumannii complex. The overall number of categorical discrepancies were: 18 very major errors (1.6%), 13 major errors (1.2%) and 22 minor errors (2.4%). EA ranged from 95.2% in P. aeruginosa to 98.1% in Enterobacterales. Screening test for ESBL phenotype was positive, indeterminate and negative in 13.7%, 32.6% and 27.4% of Enterobacterales isolates tested by both VITEK (R) REVEAL (TM) and the reference method, showing 100% CA. Conclusions: VITEK (R) REVEAL (TM) represents a reliable tool to obtain antimicrobial susceptibility results of the main Gram-negative species directly from positive blood cultures with time to results of less than 8 h.
Detection of volatile organic compounds as new paradigm to accelerate antimicrobial susceptibility testing: performance evaluation of VITEK® REVEAL™
Bianco, Gabriele
;Broccolo, Francesco
;
2024-01-01
Abstract
Objectives: The measurement of VOCs release in the headspace of a bacterial culture represents a new approach to rapidly assess antimicrobial susceptibility. Herein, we evaluated the diagnostic performance of the VITEK (R) REVEAL (TM) system directly from a collection of Gram-negative positive blood cultures. Materials and methods: One hundred and twenty-eight positive blood cultures were included in the analysis (Enterobacterales, n = 95; Pseudomonas aeruginosa, n = 21; Acinetobacter baumannii complex, n = 12). Samples were processed using VITEK (R) REVEAL (TM) according to the manufacturer's recommendations, and MICs of 22 antimicrobials were compared with those obtained using reference methods. Categorical agreement (CA), essential agreement (EA) and categorical errors were calculated. Results: Overall, 2220 strain/antibiotic pair combinations were analysed. Of these, most were classified as resistant by reference antimicrobial susceptibility testing (1091/2220; 48.7%). The overall CA and EA were 97.6% and 97.7%, respectively. CA ranged from 97.5% in Enterobacterales to 97.9% in both P. aeruginosa and A. baumannii complex. The overall number of categorical discrepancies were: 18 very major errors (1.6%), 13 major errors (1.2%) and 22 minor errors (2.4%). EA ranged from 95.2% in P. aeruginosa to 98.1% in Enterobacterales. Screening test for ESBL phenotype was positive, indeterminate and negative in 13.7%, 32.6% and 27.4% of Enterobacterales isolates tested by both VITEK (R) REVEAL (TM) and the reference method, showing 100% CA. Conclusions: VITEK (R) REVEAL (TM) represents a reliable tool to obtain antimicrobial susceptibility results of the main Gram-negative species directly from positive blood cultures with time to results of less than 8 h.I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.