Monitoring chemotherapeutic drug concentrations directly at the tumor site remains a critical unmet need in oncology, as conventional pharmacokinetic assessments based on systemic circulation fail to capture the spatial and temporal heterogeneity of drug distribution within solid tumors. Here, we report a bioresorbable, multiparametric optical sensor designed for the in situ detection of the chemotherapeutic agent doxorubicin. The sensor integrates a nanostructured porous silica scaffold with a molecularly imprinted polymer (MIP) synthetic receptor that provides shape- and chemistry-selective recognition of doxorubicin molecules. Molecular binding events are transduced through two orthogonal optical signals: i) shifts in effective optical thickness and ii) fluorescence intensity changes, enabling accurate and self-validating quantification across clinically relevant concentration ranges. The sensor operates reliably in serum with a limit of detection as low as 0.1 µg/mL, and exhibits reversible performance with minimal signal drift (<15.3%) over 12 weeks —consistent with standard chemotherapy regimens. In vivo implantation studies in mice confirm biodegradation and biocompatibility, with no evidence of local or systemic toxicity. This platform introduces a versatile strategy for multiparametric, bioresorbable chemical sensing using MIP synthetic receptors, establishing a foundation for future implantable diagnostics in precision chemotherapy.

Multiparametric Bioresorbable Sensor for Doxorubicin Detection via Molecularly Imprinted Synthetic Receptors

Tiziano Di Giulio;Muhammad Ibrar Asif;Cosimino Malitesta;Elisabetta Mazzotta
;
2026-01-01

Abstract

Monitoring chemotherapeutic drug concentrations directly at the tumor site remains a critical unmet need in oncology, as conventional pharmacokinetic assessments based on systemic circulation fail to capture the spatial and temporal heterogeneity of drug distribution within solid tumors. Here, we report a bioresorbable, multiparametric optical sensor designed for the in situ detection of the chemotherapeutic agent doxorubicin. The sensor integrates a nanostructured porous silica scaffold with a molecularly imprinted polymer (MIP) synthetic receptor that provides shape- and chemistry-selective recognition of doxorubicin molecules. Molecular binding events are transduced through two orthogonal optical signals: i) shifts in effective optical thickness and ii) fluorescence intensity changes, enabling accurate and self-validating quantification across clinically relevant concentration ranges. The sensor operates reliably in serum with a limit of detection as low as 0.1 µg/mL, and exhibits reversible performance with minimal signal drift (<15.3%) over 12 weeks —consistent with standard chemotherapy regimens. In vivo implantation studies in mice confirm biodegradation and biocompatibility, with no evidence of local or systemic toxicity. This platform introduces a versatile strategy for multiparametric, bioresorbable chemical sensing using MIP synthetic receptors, establishing a foundation for future implantable diagnostics in precision chemotherapy.
File in questo prodotto:
File Dimensione Formato  
Advanced Science - 2026 - Corsi - Multiparametric Bioresorbable Sensor for Doxorubicin Detection via Molecularly Imprinted-2.pdf

accesso aperto

Tipologia: Versione editoriale
Licenza: Creative commons
Dimensione 2.26 MB
Formato Adobe PDF
2.26 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11587/578146
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact